Intumescent FD30/60 Grill Pack 400 x 400with 2x SAA Vents

Stock Code: INTGRILLKIT400X400
1-2 day lead time
£105.51 (exc VAT) per 1
Quantity: - +

Overview

  • Fire Grilles tested to: BS 476: Part 22 1987.
  • Comprehensive range of fire grille sizes.
  • For use in solid timber fire doors & solid block walls.
  • Suitable for mounting up to 1,000mm (1m) from floor level. Top edge of Grille should be no higher than 1,000mm (1m).
  • In excess of 30 or 60 minutes fire rating.
  • Vermin proof wire mesh 80% free area.

A durable ventilation grille which is easily mounted in solid timber fire doors & solid block walls, and can provide in excess of 1/2 or 1 hour fire protection. Astroflame Fire Grille comprises of a intumescent core within a galvanized steel frame with vermin proof 6mm steel mesh fitted to both faces.

Suitable for fitting up to 1,000mm (1m) from floor level. The top of the grille should not be higher than 1000mm from the floor.

The design allows a free area of 80% approximately. See our Free Area table below for guidance.

All square and rectangular grilles are available to suit 30 minute or 60 minute on previously fire rated applications. Please note these fire grilles are tested with a Steel face Plate (Astro Plates) either side.

Maximum single grille size is 600 x 600 mm.

Line the aperture with Astro INTU Mastic and mechanically fix the Grille in place with steel screws in each corner and at 150mm centres both sides.

 

Installation

We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted.

 

Maintenance

All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 – Code of Practice for the Installation and Inspection of Fire Stopping.

 

Competency

It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.

 

Additional Notes

How do I install a fire grille (AstroGrille)